Page tree
Skip to end of metadata
Go to start of metadata

All outdoor devices are equipped with indoor power supply units. Exact type of IDU, which is used with each device model is specified in different models description (see below).

Indoor AC/DC injector with integrated lighting protection IDU-CPE

Figure - IDU-CPE top view

IDU-CPE  is an indoor AC/DC PoE injector. It is designed only for R5000-Smn, R5000-Lmn and synchronization hub AUX-ODU-SYNC and has integrated lighting protection.

ParameterDescription
Input voltage (AC)100 ... 240 V
Output voltage+ 48 V
Power consumption24 W
Size and weight87x78x36,5 (LxWxH), 0.15 kg
Operating temperature0 °С ... +40 °С
IEC compatibilityEN61000-4
Table - IDU-CPE Specification

Figure - IDU-CPE front panel view

Figure - IDU-CPE rear panel view

Figure – IDU-CPE Outline Drawing

Indoor AC/DC injector with integrated lighting protection IDU-BS-G

Figure - IDU-BS-G Top View

Indoor Gigabit PoE Injector with lightning protection for InfiLINK 2x2 and InfiMAN 2x2 family (except R5000-Qmxb).

ParameterDescription
Size125*72*38 mm (L*W*H)
Connectors and Interfaces
  • ETH IN - Ethernet input (Data only)
  • ETH OUT - Ethernet output (Data+VDC), PASSIVE PoE
  • PWR - AC Input (100-240 V)
Supported Ethernet Modes10/100/1000Mbps (Gigabit Ethernet pass-through)
Output Voltage & Current+56 V, 0.9 A (50.4W Max)
Operating temperature range 0 °С ... +40 °С
Ethernet Connectors Pin-out

ETH IN:

PinDescription
1Data pair A+
2Data pair A-
3Data pair B+
4Data pair C+
5Data pair C-
6Data pair B-
7Data pair D+
8Data pair D-

ETH OUT:

PinDescription
1Data pair A+
2Data pair A-
3Data pair B+
4+VDC + Data pair C+
5+VDC + Data pair C-
6Data pair B-
7-VDC + Data pair D+
8-VDC + Data pair D-
EMC

Meet:

  • FCC Class B
  • EN55022 Class B
Lightning Protection

In compliance with:

  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
Table - IDU-BS-G Specification

Figure - IDU-BS-G Front Panel



 

Figure - IDU-BS-G Rear Panel

Indoor AC/DC injector with integrated lighting protection IDU-BS-G(60W)


Figure - IDU-BS-G(60W)

Indoor Gigabit PoE Injector with lightning protection for InfiLINK XG, InfiLINK XG 1000 families and R5000-Qmbx model of the InfiMAN 2x2 family.

ParameterDescription
Size151*62*38 mm (L*W*H)
Weight0.32 kg
Connectors and Interfaces
  • "ETH IN" - Ethernet input (Data only)
  • "ETH OUT" - Ethernet output (Data+VDC), PASSIVE PoE
  • "PWR" - AC Input
Supported Ethernet Modes
  • 10/100/1000Mbps (Gigabit Ethernet pass-through)
Input Voltage
  • 100 ... 240 V
Output Voltage & Current
  • +55 V, 1.5 A
Consumption
  • 60 W over 4-pairs (Guaranteed)
Operating temperature range
  • -10 °С ... +40 °С
Pin Assignment and Polarity
  • Data Pairs 1/2 (-) and 3/6 (+)
  • Spare Pairs 7/8 (-) and 4/5 (+)
EMC

Meet:

  • FCC Part 15, Class B
  • EN 55022 Class B (Emissions)
  • EN 55024 (Immunity), VCCI
Lightning Protection

In compliance with:

  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
Table - IDU-BS-G(60W) Specification


Figure - IDU-BS-G(60W) Front Panel



 

Figure - IDU-BS-G(60W) Rear Panel

Indoor DC/DC injector with integrated lightning protection IDU-CPE-DC

Figure - IDU-CPE-DC top view

IDU-CPE-DC is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership. It is desinged for all CPE units (Smn and Lmn) and has integrated lightning protection. The source of DC power supply can be +48 V or even -48 V, hence installation of CPE units is possible where other DC or AC power sources are unavailable.

ParameterDescription
Compatible modelsInfiLINK 2x2 and InfiMAN 2x2 series CPE ODU (Smn and Lmn)
Connectors and Interfaces
  • "Switch HUB" - Ethernet input
  • "RJ45" - Ethernet output (data+VDC, protected leg)
  • "VIN+" - DC+ Input
  • "VIN–" - DC– Input
  • "FG" - ground clamp
Supported Ethernet Modes
  • 10/100 Mbps (Fast Ethernet pass-through)
Input voltage
  • ±36 ... 72 V
Output voltage
  • +48 V, 0.5 A
Power consumption
  • 27 W
Ethernet Connectors Pinout
  • Ethernet Input:
PinDescription
4Not Connected
5Not Connected
7Not Connected
8Not Connected


  • Ethernet Output:
PinDescription
4+VDC
5+VDC
7-VDC
8-VDC
Compliance
  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning), 20A (tp = 8/20us)
  • UL1950, CSA 22.2 & TUV EN60950
  • FCC Class B , EN55022 Class B, EN60945, EN50155
Size and Weight85x57x36 mm, 0.15 kg
Table - IDU-CPE-DC Specification

Figure - Connection scheme

IDU-CPE-DC Packing List

ComponentDescription

  • IDU-CPE-DC
Table - IDU-CPE-DC Packing List

Indoor DC/DC injector with integrated lightning protection IDU-LA-G(V.01)


Figure - IDU-LA-G(V.01) top view

IDU-LA-G(V.01) is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership.

IDU-LA-G(V.01) may be used for the following purposes:

  • To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on ODU.
  • To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind power sources).

In both cases IDU-LA-G(V.01) should be properly grounded (please refer to the “Grounding and Lightning Protection” section of this manual).

Figure - IDU-LA-G front panel view

Figure - IDU-LA-G(V.01) inside view

Size 115×65×40 mm (L×W×H), weight 0.15kg

 

Figure - Mounting holes sizes

Input voltage supported for InfiNet Wireless models and devices.

Input voltage, VDCModel

+9…+56

R5000-SmnR5000-LmnR5000-SmnbR5000-SmncR5000-Lmnc


±43…±56R5000-MmxR5000-OmxR5000-MmxbR5000-OmxbR5000-QmxbUmXmAUX-ODU-SYNC



Table - Input voltage

CAUTION

Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe power requirements!

IDU-LA-G(V.01) Packing List

ComponentDescription

  • IDU-LA-G(V.01)

  • Connector and cable assembly
    • Connector: DC plug, on cable, 2,1х5,5х9 mm
    • Сable length: 1,5 ... 1,6 m

  • Standard RJ-45 (2 pcs)

  • Shielded RJ-45 (1 pcs)



Table - IDU-LA-G(V.01) Packing List

Outdoor DC/DC injector with lightning protection AUX-ODU-INJ-G


Figure - AUX-ODU-INJ-G

Optional indoor/outdoor DC injector with built-in lightning protection. It greatly reduces complexity of the deployment in the cases where DC source is available on the rooftop eliminating the need of weather-sealed cabinets.

ParameterDescription
Size and Weight34x94x121 mm, 0.28 kg
Connectors and Interfaces
  • ETH IN - Ethernet input
  • ETH OUT - Ethernet output (data+VDC, protected leg)
  • PWR - DC Input
  • GND - Ground clamp
Supported Ethernet Modes
  • 10/100/1000 Mbps (Gigabit Ethernet pass-through)
Water and Dust Protection
  • IP66 and IP67
Operating temperature range
  • -55 °C ... +60 ºC
DC Range
  • Xm, Um
  • R5000-Mmx, R5000-Omx, R5000-Mmxb, R5000-Omxb

±43...±56 VDC 

  • R5000-Smn, R5000-Lmn, R5000-Smnb, R5000-Smnc, R5000-Lmnc

+9... +56 VDC (positive voltage only)

CAUTION

Using inappropriate DC source will damage the ODU, which will be not covered by warranty

Ethernet Connectors Pin-out

ETH IN:

PinDescription
1Data pair A+
2Data pair A-
3Data pair B+
4Data pair C-
5Data pair C+
6Data pair B-
7Data pair D+
8Data pair D-

ETH OUT:

Pin

Description

1

Data pair A+

2

Data pair A-

3

Data pair B+

4

+VDC + Data pair C-

5

+VDC + Data pair C+

6

Data pair B-

7

-VDC + Data pair D+

8

-VDC + Data pair D-

Lightning Protection

In compliance with:

  • GR-1089
  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)
  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)
  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)
  • ETSI ETS 300 386
Table - AUX-ODU-INJ-G Specifications

AUX-ODU-INJ-G Packing List

ComponentDescription

  • AUX-ODU-INJ-G

  • Cable gland (3 pcs)

  • Clamp (2 pcs)

  • Standard RJ-45 (1 pcs)

  • Shielded RJ-45 (1 pcs)

  • Connector
Table - AUX-ODU-INJ-G Packing List



Figure - AUX-ODU-INJ-G Supply package